• Features The 303B offers highly accurate portable measurement of trace moisture in gas streams for division 2 areas. Using an electrolytic (P2O5) sensor, the 303B can be used to monitor nearly all gases. It is compact, lightweight, and suitable for both portable use and permanent installation in Class I Div. 2 areas. With the optional carrying bag and lightweight design, the 303B is truly portable. APPLICATIONS : The 303B is designed to measure moisture content in gases such as air, nitrogen, argon, natural gas, and others with comparable characteristics. Typical applications are:
    • Monitoring natural gas pipelines and gas treatment processes
    •  Monitoring air humidity in dry boxes
    • Continuous monitoring of atmospheres in simulated space chambers
    • Sensing elements in humidity control systems
    • Monitoring inert protective atmospheres in brazing or sintering furnaces
    • Monitoring moisture in many fluorocarbon gases
    • Constant measurement of batch and continuous driers to assure quality control without the expense of overdrying
    • Monitoring anhydrous batch chemical processes at startup
    • Quality control of transistor and diode backfill gas
    • Instrument air systems
    • Cryogenic processes
    • Radar waveguides
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features Based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) The 5100P analyzer provides simple, easy-to-use moisture analysis using tunable diode laser absorption spectroscopy (TDLAS) in a durable, lightweight, and mobile package for measurements in natural gas. Designed to be intuitive to start-up and log data, the 5100P is the tool-of-choice for users needing to perform measurements in remote locations or verify fixed analyzer installations.
    • Fast response, highly accurate measurements
    • Integrated sample system removes contaminants
    • Rechargeable battery for at least 8 hours of operation
    • Lightweight package simplifies transporting the device between locations
    • Certified for use in hazardous areas
    • Minimal maintenance required
    • Measurement confidence
    • Increased efficiency
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features ACCURATE DETERMINATION OF THE DEW POINT OF NATURAL GAS The Chanscope IITM was designed to meet the need for a user friendly dew point tester. It measures the dew point of the sample gas through the use of a chilled mirror as required by ASTM D1142. This device bears a number of significant improvements to usability over the standard dew point tester:
    • The mirror is illuminated making it much easier to see dew formation and identify the type of dew on the mirror
    • The temperature of the mirror is displayed above the mirror itself electronically thereby making it much easier to identify the exact temperature at which the dew forms.
    • The temperature sensor operates over the full range of possible dew points thereby eliminating the need to have multiple testers of varying dew point range
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features The Ranarex Portable Gas Gravitometer is an easy-to-use, fast responding gas gravitometer that is used to determine the specific gravity of a process gas as compared with air. This unit offers multiple scales and field-proven accuracy within 0.05% of actual value at any reading. Dual ranges are available: 0.52-1.03 and 0.097-1.90 relative density (specific gravity). Plant and process operators need a reliable, simple means of confirming the quality or mixture of process gases. The means used to perform these tests must be reliable, accurate, and very affordable. For many processes and situations, gas quality can be easily inferred through a simple analysis of the gas mixture's specific gravity as opposed to a complex spectral analysis. Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features Natural gas pipeline operations are dramatically impacted by the presence or formation of liquids within the gas pipeline. The dew point of the natural gas must be periodically checked in order to ensure that troublesome liquid formation is not occuring in the pipeline. Operators and technicians need an accurate, rugged means of determining the dew point of the gas within the pipeline. This device is completely manual. The observor is not only the 'detector', they must also manually control the rate of mirror cooling and read the indicated temperature at the appropriate time. When used by a skilled operator, this device will produce extremely accurate dew point measurements. The Standard Dew Point Tester, is available in a variety of dew point temperature and pressure ranges. The Solution This industry need was met with the development of the Standard Dew Point Tester. The device works as follows: The sample gas to be analyzed is slowly passed, at pipeline pressure, over a mirror. The mirror is slowly cooled through the use of a manually regulated refrigerant gas. A thermometer accurately reads the temperature of the mirror while an operator observes the mirror for the formation of dew. When dew is observed, the dew point temperature is read off the thermometer. The type of dew formed on the mirror can be determined by an experienced user. Use of this device is described by ASTM D1142. Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details

Title