Product & Service

Home/Product & Service
  • Special Features & Benefits Pressure-seal Check Valve conforms to ASME B 16.34. CE Marking - Meets requirements of Pressure Equipment Directive 2014/68/EU, Annexure III, Module H Atex - Meets requirements of Atex Directive 94/9/EC (ATEX), category 2 non-electrical equipment Safety Integrity Level for Automated Valves - SIL 3 certification available Valves in intermediate reduce cost of ownership Pressure-Seal mechanism utilizes line pressure to enhance seal; ensures sealing integrity at higher operating pressures. Higher hardfacing thickness (3 mm) to ensure consistent hot hardness Customised deposition process in F91/ C12A valves to avoid delamination of hardfaced surfaces Live loading of bonnet bolts for F91/ C12A valves
    Details
  • Check Valves
    • Pressure-Seal mechanism utilizes line pressure to enhance seal; ensures sealing integrity at higher operating pressures. Customised deposition process in F91/ C12A valves to avoid delamination of hardfaced surfaces Live loading of bonnet bolts for F91/ C12A valves
    Special Features & Benefits Check Valve design complies to BS 1868 and API 594 Offered with API monogram Fugitive Emissions - Complies with ISO 15848-1 (<50 ppm) Compliance to Annex III Module H of Pressure Equipment Directive 2014/68/EU Check valves successfully tested to Shell 77/300 and witnessed by Shell Inspectors Tilting disc and Axial Flow check valves can be also offered Internal hinge design, no hole in the body, eliminates leakage path Inconel overlay/ cladded option available
    Details
  • Features ACCURATE DETERMINATION OF THE DEW POINT OF NATURAL GAS The Chanscope IITM was designed to meet the need for a user friendly dew point tester. It measures the dew point of the sample gas through the use of a chilled mirror as required by ASTM D1142. This device bears a number of significant improvements to usability over the standard dew point tester:
    • The mirror is illuminated making it much easier to see dew formation and identify the type of dew on the mirror
    • The temperature of the mirror is displayed above the mirror itself electronically thereby making it much easier to identify the exact temperature at which the dew forms.
    • The temperature sensor operates over the full range of possible dew points thereby eliminating the need to have multiple testers of varying dew point range
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Cartridge heaters are high efficiency heating elements. Diameters of cartridge heaters range from 0.25" to 1.25". Watt densities from 25 W/in2 to 200 W/in2 and sheath temperatures to 1800°F. Optional end seals resist contaminants and moisture from entering inside the heater. Chromalox provides a variety of sizes, wattage ratings, voltages and protective features to meet many challenging applications.
    Details
  • Features ABS Adjustable Busbar Support Profile
    • For use with ABS Adjustable Busbar Support Insulator Modules
    • Drill holes in field for custom distances between phases
    • Improve bending resistance by interlocking or stacking two profiles
    • Attach profiles together or attach profile to the panel structure using ABS Adjustable Busbar Support Profile  Stiffener
    • RoHS compliant
    3.4 ABS ABS Adjustable Busbar Support Perforated Profile
    • For use with ABS Adjustable Busbar Support Insulator Modules
    • Factory punched holes for quick assembly
    • Improve bending resistance by interlocking or stacking two profiles
    • Attach profiles together or attach profile to the panel structure using ABS Adjustable Busbar Support Profile Stiffener
    • RoHS compliant
    3.4 ABS perforated ABS Adjustable Busbar Support Insulator Module
    • Modules provide flexibility to select distance between phases and supports
    • Extremely robust construction
    • Halogen free insulators
    • RoHS compliant
    3.4 ABS insulator Adjustable Flat Busbar Support Kit
    • Kit includes rail, insulators and mountable extension arms
    • Adjustable distances between phases
    • Adjusts quickly to accommodate multiple busbar thicknesses
    • High resistance to short-circuit forces
    • Provides excellent electrical protection for equipment
    • Three phase with neutral circuit
    • Halogen free
    • RoHS compliant
    3.4 Flat busbar kit CABS Busbar Support Kit
    • For all busbar types and nVent ERIFLEX Erilink busducts
    • Improve bending resistance by interlocking or stacking two profiles
    • Quick and easy to install
    • Halogen free insulators
    • RoHS compliant
    3.4 CABS CFBS Flat Busbar Support
    • Universal busbar support
    • End cover available to prevent busbar from sliding out of position
    • Clips available to accommodate multiple busbar widths
    • RoHS compliant
    3.4 CFBS FBS Flat Busbar Support
    • Support for threaded busbars
    • Three phase with neutral circuit
    • Plastic positioning pin for bar location
    • Adjusts quickly to accommodate multiple busbar widths
    • Protection screen can be fixed using spacers
    • A ground can be mounted on either side
    • Halogen free Material: Steel; Glass Fibre Reinforced Polyamide; Aluminum
    3.4 FBS FBSS Flat Busbar Support
    • Supports busbars at an angle for easy connections
    • Includes mounting holes for direct fixing of protection screen
    • Adjustable arms for easy mounting
    • Three phase with neutral circuit
    • Halogen free
    3.4 FBSS UCFBS-60-T Busbar Support
    • Universal busbar support
    • End cover available to prevent busbar from sliding out of position
    • Halogen free
    • RoHS compliant
    3.4 UCFBS 60T UCFBS-60-TN Busbar Support
    • Universal busbar support
    • Three phase with neutral circuit
    • End cover available to prevent busbar from sliding out of position
    • Halogen free
    • RoHS compliant
    3.4 UCFBS 60TN BS-125A Four Pole Insulating Support
    • Create custom four pole distribution blocks for an electrical distribution system
    • Protection screen can be attached directly to the support
    • Includes screws to mount threaded copper busbars
    • Clips on to DIN rail using DR-CLIP or mounts with screws
    • Halogen free
    • RoHS compliant
    3.4 BS 125A BS-250A Four Pole Insulating Support
    • Create custom four pole distribution blocks for an electrical distribution system
    • Mounts with screws
    • Protection screen can be fixed using spacers
    • Halogen free
    • RoHS compliant
    3.4 BS 250A BS-400A Four Pole Insulating Support
    • Create custom four pole distribution blocks for an electrical distribution system
    • Protection screen can be attached directly to the support
    • Includes screws to mount threaded copper busbars
    • Easily clips onto DIN rail or mounts to panel with screws
    • Halogen free
    • RoHS compliant
    3.4 BS 400A Universal Busbar Support 3.4 universal busbar support Universal Busbar Support with Neutral Circuit 3.4 universal neutral circuit Universal Busbar Support, High Ampacity 3.4 universal high ampacity Universal Busbar Support with Neutral Circuit, High Ampacity 3.4 universal neutral high ampa
    • Universal fixing system
    • Installs quickly and easily
    • Extremely robust construction
    • Adjustable arms for easy mounting
    • Halogen free insulators
       
    Details
  • BLZ 7.50 Female plugs with clamping-yoke screw wire-connect system. The female plugs provide space for labelling and can be coded.
    Details
  • Special Features & Benefits Fugitive Emissions - Complies to ISO 15848-1: 2006 Class AH leakage SIL3 Safety Integrity Level for Automated Valves The bellows lifecycle is designed as per MSS SP-117 Metal bellows seal the moving stem and increase durability of packed stem seal valves Bellow provide a barrier between the stem at its point of entry through the pressure boundary and the process fluid within the valve, to eliminate stem leakage An anti-rotation device is provided in the bonnet to ensure bellow does not get twisted during assembly and disassembly or by vibration Bellow-sealed valves are usually leak tested using a mass spectrometer to detect leakage rates below 1x10E-06 std.cc/sec. Bellow-sealed bonnets are backed up with a standard stem packing set and a leakage monitoring port between the bellows and the packing in order to prevent catastrophic release of hazardous fluid in the event of a bellows leak.
    Details
  • Two-row female plug with PUSH IN spring connection · the wire-entry area and handling area are clearly separated · Integrated push-buttons for opening the terminal point · High component density because of low heights · Optional: locking and releasing require no tools when using Weidmüller's · release latch (LR) or release lever (LH)
    Details
  • Assortment Workshops and factories prefer well-organised sets of tools. That results in minimal searching and preparation, and that saves money. Weidmüller implements such knowledge when combining products, characterised by good benefits for users and good functionality. Weidmüller Crimp Sets for cutting, stripping and crimping wire end ferrules provide users with practical toolkits. Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Paper
    • Steel
    • Pulp & Paper
    • Electronic
    • Renewable Energy
    • Transportation
    Details
  • Series: ASIP (Syphon) Size Max. 400 bar - Cooling adapters, hunting horn siphons, U-type siphons - Steel and stainless steel - Max. 400 °C - Max. 400 bar
    Details
  • Series: ARPX (Shut-off valve) Size Max. 400 bar - Gauge cocks in brass - Gauge valves in brass, steel and stainless steel - With or without test flanges - Isolating of pressure gauges from the process fluid
    Details
  • Series: ARA (Pulsation dampener) Size Max. 600 bar - Improves readability of pressure gauges - Reduces the effect of pulsations - Max. 600 bar - Max. 250 °C - Option: NACE conform
    Details
  • Special Features & Benefits Enhanced reliability, Longer service life Tight sealing, Consistent low torque Assured shaft sealing One-piece blowout-proof Shaft Reliable Drive - Positive shaft-disc connection Lower resistance to flow - Contoured disc Ease of installation Integral actuator mounting platform  
    Details
  • Series: AORP (Pressure limiter) Size Max. 700 bar - For corrosive gasses and liquids - Protection of instruments from over pressure - For pressure gauges, pressure switches and transmitters - Option: NACE conform
    Details
  • Analogue signal processing When used for industrial monitoring applications, sensors can record ambience conditions. Sensor signals are used within the process to continually track changes to the area being monitored. Both digital and analogue signals can occur. Normally an electrical voltage or current value is produced which corresponds proportionally to the physical variables that are being monitored Analogue signal processing is required when automation processes have to constantly maintain or reach defined conditions. This is particularly significant for process automation applications. Standardised electrical signals are typically used for process engineering. Analogue standardised currents / voltage 0(4)...20 mA/ 0...10 V have established themselves as physical measurement and control variables. Weidmüller meets the ever increasing challenges of automation and offers a product portfolio tailored to the requirements of handling sensor signals in analogue signal processing The analogue signal processing products can be used universally in combination with other Weidmüller products and in combination among each other. Their electrical and mechanical design is such that they require only minimal wiring efforts. Housing types and wire-connection methods matched to the respective application facilitate the universal use in process and industrial automation applications. The product line includes the following functions: Isolating transformers, supply isolators and signal converters for DC standard signals Temperature measuring transducers for resistance thermometers and thermocouples, frequency converters, potentiometer-measuring-transducers, bridge measuring transducers (strain gauges) trip amplifiers and modules for monitoring electrical and non-electrical process variables AD/DA converters displays calibration devices The products mentioned are available as pure signal converters / isolation transducers, 2-way/3-way isolators, supply isolators, passive isolators or as trip amplifiers. When used for industrial monitoring applications, sensors can record ambience conditions. Sensor signals are used within the process to continually track changes to the area being monitored. Both digital and analogue signals can occur. Normally an electrical voltage or current value is produced which corresponds proportionally to the physical variables that are being monitored Analogue signal processing is required when automation processes have to constantly maintain or reach defined conditions. This is particularly significant for process automation applications. Standardised electrical signals are typically used for process engineering. Analogue standardised currents / voltage 0(4)...20 mA/ 0...10 V have established themselves as physical measurement and control variables. Weidmüller meets the ever increasing challenges of automation and offers a product portfolio tailored to the requirements of handling sensor signals in analogue signal processing The analogue signal processing products can be used universally in combination with other Weidmüller products and in combination among each other. Their electrical and mechanical design is such that they require only minimal wiring efforts. Housing types and wire-connection methods matched to the respective application facilitate the universal use in process and industrial automation applications. The product line includes the following functions: Isolating transformers, supply isolators and signal converters for DC standard signals Temperature measuring transducers for resistance thermometers and thermocouples, frequency converters, potentiometer-measuring-transducers, bridge measuring transducers (strain gauges) trip amplifiers and modules for monitoring electrical and non-electrical process variables AD/DA converters displays calibration devices The products mentioned are available as pure signal converters / isolation transducers, 2-way/3-way isolators, supply isolators, passive isolators or as trip amplifiers. When used for industrial monitoring applications, sensors can record ambience conditions. Sensor signals are used within the process to continually track changes to the area being monitored. Both digital and analogue signals can occur. Normally an electrical voltage or current value is produced which corresponds proportionally to the physical variables that are being monitored Analogue signal processing is required when automation processes have to constantly maintain or reach defined conditions. This is particularly significant for process automation applications. Standardised electrical signals are typically used for process engineering. Analogue standardised currents / voltage 0(4)...20 mA/ 0...10 V have established themselves as physical measurement and control variables. Weidmüller meets the ever increasing challenges of automation and offers a product portfolio tailored to the requirements of handling sensor signals in analogue signal processing The analogue signal processing products can be used universally in combination with other Weidmüller products and in combination among each other. Their electrical and mechanical design is such that they require only minimal wiring efforts. Housing types and wire-connection methods matched to the respective application facilitate the universal use in process and industrial automation applications. The product line includes the following functions: Isolating transformers, supply isolators and signal converters for DC standard signals Temperature measuring transducers for resistance thermometers and thermocouples, frequency converters, potentiometer-measuring-transducers, bridge measuring transducers (strain gauges) trip amplifiers and modules for monitoring electrical and non-electrical process variables AD/DA converters displays calibration devices The products mentioned are available as pure signal converters / isolation transducers, 2-way/3-way isolators, supply isolators, passive isolators or as trip amplifiers.
    Details
  • AN-6100C Annunciator Simple to install, configure and operate and flexible to change, expand and grow to meet future requirements. The AN-6100C has all these qualities along with reliable operation for your most critical needs. The AN-6100C is a maintenance free; once installed, you will never have to worry about it.
    Details
  • AN-3200 Annunciator AMETEK’s new AN-3200 Annunciator brings alarm monitoring to a new level. It features long life, reliable LED illumination for local viewing of alarms and a host of communication options to connect to other devices. Alarms can be viewed remotely via a standard web browser using a built-in web server. The web browser displays a graphic image for each event with the date and time of the occurrence.

    Dual independent communication ports (RS-232/485 and Ethernet) are available to transmit alarms to other devices. The AN-3200 can receive alarms using communication ports, eliminating the need to connect digital inputs and associated wiring.

    The AN-3200 supports Modbus, DNP and ASCII protocols. The AN-3200 has a built-in web server for displaying alarms remotely via a standard web browser. All of your alarms can include a time stamp, synchronized by IRIG-B or internal clock. Time stamps can be presented through Modbus, DNP, OPC, or to a local printer or terminal for viewing.

    Installation and wiring is simplified and, in most cases, the power supply is built into the annunciator. While all systems are preconfigured to specifications, the software configuration tool allows users to make easy modifications without changing PCB board jumpers.

    Window legends are printed on standard transparency film, making them easy to change at any time. All features and options are field selectable and upgradeable.
    Details
  • AN-3100D Annunciator

    REPLACED BY AN-3200

    All of your alarms can include time stamp, synchronized by IRIG-B or our internal clock. This can be presented through Modbus, DNP, OPC or to a local printer or terminal for viewing. Dual ports (serial and Ethernet) can be provided for simultaneous connections to different devices.

    Details
  • Series: AMFD (Manifold) Size Max. 420 bar - For corrosive gasses and liquids - Isolating, purging and calibration of measuring instruments - For pressure gauges, pressure switches and transmitters - Gauge, absolute and differential pressure - Full stainless steel - Option: NACE conform
    Details
  • Aluminium Enclosure The Klippon® brand has long stood for competence and quality in housings – particularly when turnkey, customer-specific solutions for standard industrial applications and applications in explosive risk zones are concerned. Improved products that meet all application requirements: this was Weidmüller's aim when modernising and upgrading the Klippon® K enclosure series. No matter what kind of application the customer is planning; Weidmüller is able to provide a wide range of aluminium enclosures precisely fitting the customer's requirements.  
    Details
  • Series: AKPL (Capillary) Size Max. 400 bar - 4 types of capillaries - 2 different internal diameters - 1 to 30 meters - Stainless steel
    Details
  • Adapters for rail mounting From the circuit board in the control cabinet: snap-on or mounting feet form the link between plug-in connectors and terminal rails. Compatible with all standard sizes: TS 15 or TS 35. Combination foot or variations available. The quick alternative to screw connections: unbeatable ease of installation and service. The mounting foot for the terminal rails allows the universal use of pluggable connection systems on the module, the enclosure and the control cabinet and avoids patchwork solutions.
    Details
  •  Type
    • Rivet installation tool
    • Wiring Duct cutting tool
    • Rivet
    Details
  • Features HCBC High Current Busbar Clamp
    •  Connects copper busbar to copper busbar, nVent ERIFLEX Flexibar or power shunt
    • Made with non-magnetic materials for high current connections between nVent ERIFLEX Flexibar and rigid busbars such as transformer terminals
    • Rigid design assures even contact pressure
    • Installs quickly and easily
    • Ideal for on site modifications
    • RoHS compliant
    1.4 HCBS FBC nVent ERIFLEX Flexibar/Cable to Busbar Clamp
    • Very compact clamp for connecting cable conductors or nVent ERIFLEX Flexibar to busbar without drilling
    • Conductor is clamped with a pressure plate
    • Clamps can be mounted and slid into position on busbar prior to connecting conductors
    • Connections can be added after busbar has been mounted
    • Single screw locks clamp and makes connection
    • EAC compliant
    • RoHS compliant
    1.4 FBC QCC nVent ERIFLEX Flexibar Clamp
    • Connects nVent ERIFLEX Flexibar to punched busbar
    • Allows for excellent electrical contact
    • Compact, space saving design
    • Installs quickly and easily
    • Ideal for on site modifications
    1.4 QCC BC Ribbed Steel Busbar Clamp
    • Connects two copper busbars together or nVent ERIFLEX Flexibar to copper busbar
    • Two ribbed plates complete with screws
    • Allows for excellent electrical contact
    • Installs quickly and easily
    • Ideal for on site modifications
    • RoHS complian
    1.4 BC FC nVent ERIFLEX Flexibar to Busbar Clamp
    • Connects nVent ERIFLEX Flexibar to copper busbar
    • Two plates complete with screws
    • Allows for excellent electrical contact
    • Installs quickly and easily
    • Ideal for on site modifications
    • RoHS compliant
     
    Details
  • Features PB Lug for Flat Braids
    • Crimp to FTCB or FRCB braids to create custom flexible connections
    • Crimped and drilled using BD Crimp and Drill Tool or Crimping Tool for Hydraulic Work Center
    • RoHS compliant
    4.5 PB lug
    Details
  • End Plate AEP 2C 2.5 - End Plate for A2C 2.5,A2C 2.5 PE AEP 2C 2.5 BL - End Plate for A2C 2.5 BL AEP 2C 4 - End Plate for A2C 4,A2C 4 PE AEP 2C 4 BL - End Plate for A2C 4 BL AEP 2C 6 - End Plate for A2C 6, A2C 6 PE AEP 2C 10/16 - End Plate for A2C 10, A2C 16, A2C 10 PE, A2C 16 PE AEP 2C 10/16 BL - End Plate for A2C 10 BL, A2C 16 BL AEP 2T 2.5 - End Plate for A2T 2.5 AEP 3T 2.5 - End Plate for A3T 2.5 AEP 4C 2.5 - End Plate for AFS 2.5 CF 2C BK, AFS 2.5 CF 2C 12V BK, AFS 2.5 CF 2C 24V BK AEP 3C 4 - End Plate for AFS 4 2C BK, AFS 4 2C 10-36V BK, AFS 4 2C 30-70V BK, AFS 4 2C 100-250V BK End Stopper AEB 35 SC/1 - A-series, End bracket Cross Connection ZQV 2.5N/10 - Cross Connection for 2.5 mm2, 10 poles ZQV 6N/4 - Cross Connection for 6 mm2, 4 poles ZQV 10N/2 - Cross Connection for 10 mm2, 2 poles ZQV 16N/2 - Cross Connection for 16 mm2, 2 poles  
    Details
  • Accessories Integrate, expand and customise: the perfect supplement to every application. Universal system accessories enable easy adaptation of the interfaces to fulfil specific requirements for the relevant application. &nbsp; The following options are available depending on the system: installing and fastening components Signalling and checking statuses Marking and labelling components Potential distribution and separation Only the right high-quality tools will ensure professional working standards. All in all: ease of operation, maximum functionality and safety for the application and the user. Industrial
    • Electronic
    • Other
    Details
  • Accessories In addition to heavy-duty connectors, RockStar® includes the appropriate accessories for effective, functional and safe system cabling; e.g. coding systems, shield clamps, cover plates and replacement seals Industrial
    • Machinery
    Details
  • The 931 uses a sophisticated UV-VIS photometer to measure any single UV-absorbing gas species for process monitoring and control. Additional IR and thermal conductivity sensors capable of detecting non-UV absorbing species, such as CO2 and H2 can be incorporated into the design. The 931 is provided as an explosion-proof package making it suitable for most chemical and petrochemical applications. Features
    • Class I, Division 1, or ATEX II 2 G Hazardous Area Rating
    • Direct measurement
    • Provision to return sample to process (with heated acid gas probe option)
    • Minimal sample conditioning
    • Dual-beam, dual-wavelength design
    • Optional detectors available (thermal conductivity-hydrogen and IR-hydrocarbon
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Power Plant
    Details
  • The 930 H2S Vapour Space Analyzer was developed for sulfur pit storage applications. The 930 has been field proven as one of the industry’s most reliable instruments for monitoring H2S and SO2. The analyzer uses a proprietary high resolution UV technology in a dual beam, multiple wavelength configuration. Resolution better than 0.02 nm is provided by high intensity, line source lamps. These sources emit at a fixed wavelength, providing great measurement stability, and emit low total power, removing the potential for sample photolysis. The dual beam configuration, combined with the reference measurement, ensures low noise performance, with minimal baseline and span drift. Features
    • Simultaneous, accurate measurement of both H2S and SO2
    • Output alarms for H2S (LEL) and SO2 (smoldering fire)
    • Common design with Model 900 (air demand) and Model 910 (stack gas)
    • Exceptional baseline stability
    • Improved sample conditioning via ASR Probe
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Power Plant
    Details

Title

Go to Top