Analyzers

Home/Analyzers
  • The 931 uses a sophisticated UV-VIS photometer to measure any single UV-absorbing gas species for process monitoring and control. Additional IR and thermal conductivity sensors capable of detecting non-UV absorbing species, such as CO2 and H2 can be incorporated into the design. The 931 is provided as an explosion-proof package making it suitable for most chemical and petrochemical applications. Features
    • Class I, Division 1, or ATEX II 2 G Hazardous Area Rating
    • Direct measurement
    • Provision to return sample to process (with heated acid gas probe option)
    • Minimal sample conditioning
    • Dual-beam, dual-wavelength design
    • Optional detectors available (thermal conductivity-hydrogen and IR-hydrocarbon
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Power Plant
    Details
  • Features AMETEK Process Instruments has been the leader in tail gas analysis for over 40 years-with more than 1,100 installed 880 NSL analyzers and more than 100 million hours of run time. The 888, the successor of the 880 NSL uses field-proven and highly reliable UV technology to accurately monitor the H2S and SO2 concentrations in sulfur recovery tail gas. This compact, rugged analyzer mounts directly on the process pipe, eliminating the complexity and safety issues of fiber optic coupled photometers. The 888 is the evolution of a well proven formula. All the best elements of the iconic 880 NSL are still there; Four year lamp life, no shelter required and steam blow back for ammonia salts. Building on this success the 888 offers improvements in a number of key areas. Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Power Plant
    Details
  • The 930 H2S Vapour Space Analyzer was developed for sulfur pit storage applications. The 930 has been field proven as one of the industry’s most reliable instruments for monitoring H2S and SO2. The analyzer uses a proprietary high resolution UV technology in a dual beam, multiple wavelength configuration. Resolution better than 0.02 nm is provided by high intensity, line source lamps. These sources emit at a fixed wavelength, providing great measurement stability, and emit low total power, removing the potential for sample photolysis. The dual beam configuration, combined with the reference measurement, ensures low noise performance, with minimal baseline and span drift. Features
    • Simultaneous, accurate measurement of both H2S and SO2
    • Output alarms for H2S (LEL) and SO2 (smoldering fire)
    • Common design with Model 900 (air demand) and Model 910 (stack gas)
    • Exceptional baseline stability
    • Improved sample conditioning via ASR Probe
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    • Power Plant
    Details
  • Features Critical moisture measurement applications include high purity gas production; olefin manufacture, storage, and transmission; semiconductor gases; and industrial gas production and quality assurance. For these applications and more, turn to the 5800 Moisture Analyzer. This analyzer offers a truly remarkable combination of performance benefits: exceptional accuracy, multi-gas compatibility, fast response speed, and wide measurement range. Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features AMETEK’s 2850 Moisture Analyzer establishes a new standard in clean gas moisture analyzers: ultrafast response speed, exceptional accuracy, virtually no interferences, multigas compatibility, and on-board measurement verification. This unique combination of capabilities makes the 2850 the moisture analyzer of choice for monitoring process desiccant dryers, instrument air dryers, or air separators, and for industrial gas production and quality assurance. Typical Applications
    • Industrial gas production and quality assurance
    • Cryogenic air separation
    • Process dryers
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features The 241CE II Hydrocarbon Dew Point Analyzer is a quality control tool for natural gas processing, distribution and consumption. Detection and measurement of hydrocarbon dewpoint is achieved in a single cell, single cycle operation. The dew point analyzer uses patented chilled-mirror technology. With the 241CE II Hydrocarbon Dew Point Analyzer, all monitoring and measuring of dew points is done automatically under control of an onboard computer, rather than by an operator. The dew point analyzer was designed for unattended operation. Accurate and objective direct measurement of hydrocarbon dew point temperature at pipeline pressure or Cricondentherm
    • Proprietary three-stage filter provides superior protection
    • Designed for unattended operation with low maintenance
    • Compact design allows mounting in optional enclosures
    • Digital communications vis Modbus RTU protocol
    • Fully integrated sample system
    • Hydrocarbon dew point temperature current output
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features 5100 Based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) The 5100 hosts a single laser platform to measure a single gas analyte. The device can measure any one of the following gas analytes: water vapor, methane, hydrogen sulfide, carbon dioxide, and oxygen in process or flue gas. If water vapor is the measured gas analyte, methane can be monitored additionally at percent levels using the same laser. A key feature of the 5100 is the use of a sealed reference cell, which contains a known amount of analyte gas measured, for referencing the emission wavelength of the laser. The use of a reference cell enables both the ability to line-lock the lasers and to continuously verify the instrument calibration. The 5100 is designed to handle sample gases with dew points as high as 55ºC. For higher temperature dew point applications the 5100HD is recommended.
    • All digital signal processing
    • Web-based interface
    • Connectivity by modbus, ethernet and analog
    • Real-time performance monitoring
    • Fully integrated sample handling
    • Resistant to contamination
    • Reference Cell enables Line Lock and Span Verification The 5100 offers high specificity, selectivity, speed of response and great reliability
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features The 3050 Moisture Analyzer series measures trace levels of moisture in a gas through the use of a quartz-crystal oscillator sample cell. AMETEK is the leader in quartz-crystal technology, which for thirty years has offered significant advantages over other measurement techniques: • Most accurate trace moisture measurement technology available • Responds far faster to both increasing and decreasing moisture levels • Specific to moisture in most applications • Provides a much more rugged sensor Because of these advantages, the quartz-crystal oscillator has become the industry standard for applications ranging from ultrahigh purity semiconductor gases to natural gas streams containing 30% H2S. Now, the 3050 analyzers bring the benefits of quartz-crystal technology to a broad spectrum of moisture applications. AME Vision Display Unit AMEVision allows users to continually monitor the measurement and diagnostic information from up to eight 3050 series moisture analyzers. AMEVision provides real-time moisture measurements, trend data, and details a variety of maintenance and troubleshooting information from the 3050. Users can communicate with AMEVision via Modbus RS485 and Ethernet LAN. • Compatible with 3050 models OLV, SLR, DO, and TE • Connect up to eight analyzers on one unit • Trend history • Automatic data capture and logging • Calibration history • Alarm history Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details
  • Features Based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) The 5100P analyzer provides simple, easy-to-use moisture analysis using tunable diode laser absorption spectroscopy (TDLAS) in a durable, lightweight, and mobile package for measurements in natural gas. Designed to be intuitive to start-up and log data, the 5100P is the tool-of-choice for users needing to perform measurements in remote locations or verify fixed analyzer installations.
    • Fast response, highly accurate measurements
    • Integrated sample system removes contaminants
    • Rechargeable battery for at least 8 hours of operation
    • Lightweight package simplifies transporting the device between locations
    • Certified for use in hazardous areas
    • Minimal maintenance required
    • Measurement confidence
    • Increased efficiency
    Industrial
    • Oil & Gas
    • Chemical & Petrochemical
    Details

Title

Go to Top